Quick Selection Table: Stroke, Accuracy, Output and Protection on One Page
Selecting a magnetostrictive displacement sensor is most tedious when parameters are flipped among a dozen series. This article compresses the Germanjet full-range core parameters into one quick-reference table: stroke, accuracy, output signal, protection class and positioning in one sentence. Pressure rating, cylinder-cap interface and resolution are written by series from — do not put Series 16’s 530 bar, Series 17’s 600 bar and Series 19 in-cylinder 300/600 bar on the same row. Lock the direction from the table first, then open the corresponding product page for detailed specifications.
Full-range magnetostrictive displacement sensor selection at a glance
Cylinder-integrated (inside the hydraulic cylinder) at a glance
External rod / rail; four-pin voltage type: see wiring red lines
19P
125–4050 mm
16-bit D/A
Analog / digital / fieldbus
IP67
External rod, aluminium profile housing
19D
75–475 mm
16-bit D/A
Analog / digital / fieldbus
IP67
Split-type, electronics housing mounted remotely
19F
2500–7600 mm
Analogue 16-bit D/A
Analog / digital / fieldbus
IP67; front dead zone 50/130 mm
Flexible tube, non-ferromagnetic guide tube
Mobile hydraulics at a glance
Series
Range
Accuracy / resolution
Output
Protection
Positioning
Series 13
50–2500 mm
Per ordered model
Voltage / analog / CANopen
IP68→IP69K
Mobile machinery, 25 g vibration
13C
50–2500 mm
Per ordered model
0.1-4.9 V voltage
IP68→IP69K
Compact, low power, voltage output
13R
75–450 mm
Per ordered model
Dual-channel redundant output
IP68→IP69K
Redundant output, safety-critical
Fieldbus types at a glance (Series 19 digital interfaces)
Series
Protocol
Features
Interface
191
Analog
16-bit D/A, dual-magnet minimum 76 mm
D60 6-pin M12
192
SSI
Absolute position, 8-32 bit
D70 7-pin
194
CANopen
DS-301, 20-1000 kbit/s
D60 6-pin
195
Profibus
DP, up to 12 Mbit/s
D53 dual M12
197
EtherCAT
DC synchronisation, 100 Mbit/s
D56 daisy-chain
198
EtherCAT
Single M12 8-pin integrated
M12 8-pin
199
PROFINET
RT/IRT, encoder Profile 4.1
D56+M8
Lock the series in three steps
Step 1: decide the mounting method — cylinder-integrated choose 16/17/19H, external rod choose 12/18/19P/19D, extra-long stroke choose 19F, mobile machinery choose Series 13. Step 2: decide the output — Series 16 can be 160/161 analogue or SSI; analogue is also 191 or Series 12/18 codes, fieldbus 194/195/197/199 by PLC protocol, safety redundancy 16R/16T/13R. Step 3: check pressure rating and interface by series — Series 16 is 350/530 bar + Ø18G7, Series 17 is 350/600 bar + M18×1.5, 19H is 300/600 bar. Detailed parameters are on the corresponding product page.