162 SSI vs 192 SSI: Series 16 in-cylinder is not Series 19
When the controller needs SSI, Germanjet has two output names: 162 and 192. The electrical figures are almost the same; the mechanics are different series. The wrong code brings a flat in-cylinder head or a Series 19 H/P/D/F mount.
Identify the series first
| 162 | 192 | |
|---|---|---|
| Series | Series 16 flat in-cylinder housing | Series 19 SSI, mounting 19H / 19P / 19D / 19F |
| Cap / pressure | Ø18G7, Ø10 rod, piston bore ≥12.7 mm; 350 bar working / 530 bar peak | Series 19 in-cylinder is 300 / 600 bar; external types are not pressure-containing |
| Connector | 7-pin D70 male | 7-pin D70 male |
| Data | Binary or Gray, 8–32 bit, 1 / 2 / 5 / 10 / 20 / 50 / 100 μm | The same set |
Output names: 160 / 161 / 162, 180–185, 190–199. Bore and pressure: Series 16 explained.
Cable length vs baud (162 and 192)
| Cable length | Max data rate |
|---|---|
| < 3 m | 1000 kBd |
| < 50 m | 400 kBd |
| < 100 m | 300 kBd |
| < 200 m | 200 kBd |
| < 400 m | 100 kBd |
Minimum clock spacing 48 μs. Longer cable means a slower SSI clock on the master. Timing: Series 192 SSI and SSI timing and Gray code.
Update rate vs stroke
| Stroke | Update rate |
|---|---|
| 300 mm | 3.7 kHz |
| 750 mm | 3.0 kHz |
| 1000 mm | 2.3 kHz |
| 2000 mm | 1.2 kHz |
| 5000 mm | 0.5 kHz |
Analogue 0.5 / 1.0 / 2.0 / 5.0 ms bands: update time vs control cycle.
How to tell the code is wrong
- The cylinder is already Ø18G7 and 350 / 530 bar, but the code is 192.
- Series 19 external or split, but the code is 162.
- D70 fits and the LEDs light, but Gray / bit length / resolution disagree with the PLC — fix the protocol, then baud vs length.
Full pin-outs against the model: contact an engineer.
Frequently Asked Questions
Q: Does Series 16 have SSI?
Yes. Series 16 SSI is 162. 192 is Series 19 SSI — do not write 162 as 192.
Q: Are the 162 and 192 baud tables the same?
Yes: 1000 kBd below 3 m, then 400 / 300 / 200 / 100 kBd below 50 / 100 / 200 / 400 m. Clock spacing 48 μs minimum.
Q: Which connector does 162 use?
7-pin D70 male, same as 192. Series 12 uses DIN 43650; 191 analogue often uses D60.
Q: Why not order on the letters SSI alone?
162 follows Series 16 mounting and 350 / 530 bar; 192 follows Series 19 mounting and pressure. Same interface, different cylinder cap.