Technical Articles & News

Germanjet news, technical articles and resources

Technical Articles (Page 9)

Long-Stroke Selection (2 m and Above): The 19F Flexible Solution and Segmented Measurement

Long-Stroke Selection (2 m and Above): The 19F Flexible Solution and Segmented Measurement

Long strokes bring four simultaneous constraints — amplified absolute error, reduced update rate, rigidity and transport — and a choice between the flexible and segmented routes.

High-Accuracy Applications: Specifying Sensors for μm-Level Closed Loops

High-Accuracy Applications: Specifying Sensors for μm-Level Closed Loops

Build the error budget before picking specifications: compress the range, separate resolution from repeatability, and account for update rate and thermal drift.

Equipment for Export: How to Read CE / ATEX / UL Certification

Equipment for Export: How to Read CE / ATEX / UL Certification

Certification is a prerequisite, not paperwork to patch together before delivery — the positioning of four systems and a seven-step verification process.

Retrofitting Legacy Equipment: Adding Position Measurement Without Touching the Cylinder

Retrofitting Legacy Equipment: Adding Position Measurement Without Touching the Cylinder

Three retrofit routes that leave the cylinder intact, six items to measure before starting, signal interfacing options, and four common mechanical installation pitfalls.

How to Read a Datasheet: The Parameter Traps in Range, Accuracy and Resolution

How to Read a Datasheet: The Parameter Traps in Range, Accuracy and Resolution

Five parameter groups — range, the three accuracy terms, temperature, protection and interface — each with the correct way to read it and the consequences of misreading it.

Practical Selection Calculations: Working Out Stroke, Installation Space and Output

Practical Selection Calculations: Working Out Stroke, Installation Space and Output

A four-step calculation method — fix the stroke, the mounting, the environment and the output — plus a pre-order selection checklist you can tick off directly.

Multi-Axis Synchronization: How Many Axes Can One Fieldbus Carry Reliably?

Multi-Axis Synchronization: How Many Axes Can One Fieldbus Carry Reliably?

Decided by the time budget of three quantities — sensor update period, bus cycle time and controller cycle — with a comparison of synchronization capability by fieldbus.

High-Pressure Cylinder Selection: Don't Get the Pressure Rating and Peak Pressure Wrong

High-Pressure Cylinder Selection: Don't Get the Pressure Rating and Peak Pressure Wrong

Pressure selection is based on the system pressure peak, not on the steady-state working pressure. Align by series: Series 16 is 530 bar peak, Series 17 is 600 bar, Series 19 in-cylinder is 600 bar.

Explosion-Protected Area Selection: Which Certification Applies to Zone 0/1/2

Explosion-Protected Area Selection: Which Certification Applies to Zone 0/1/2

The zone classification determines which protection types are permitted, and three further items must be checked: equipment protection level, gas group and temperature class.

High-Temperature Selection: The Dual Constraint of Oil Temperature and Ambient Temperature

High-Temperature Selection: The Dual Constraint of Oil Temperature and Ambient Temperature

The rod is limited by oil temperature and the electronics head by ambient temperature; the two boundaries are independent, and exceeding either one causes failure.

Magnetostrictive vs. Potentiometer / Resistive Scale: Life, Failure Modes and Total Cost of Ownership

Magnetostrictive vs. Potentiometer / Resistive Scale: Life, Failure Modes and Total Cost of Ownership

Comparing the selection boundary between magnetostrictive sensors and potentiometric resistive scales in terms of sensing mechanism, failure mode, protection capability and TCO composition.

Magnetostrictive vs. Capacitive / Eddy Current: How to Choose for Short-Range High Accuracy

Magnetostrictive vs. Capacitive / Eddy Current: How to Choose for Short-Range High Accuracy

Capacitive and eddy-current sensors measure a millimetre-scale gap; magnetostrictive sensors measure absolute position along a stroke — they are not solutions to the same problem.